Master Electrician Exam (NEC)Load CalculationsMedium

A master electrician is calculating the feeder demand load for a multi-family dwelling with 20 similar dwelling units. Each unit has an 8 kW electric range. According to NEC Article 220.55, what is the minimum demand load for the electric ranges?

  1. A25 kW
  2. B40 kW
  3. C35 kW
  4. D50 kW
Show answer & explanation

Correct answer: C. 35 kW

According to NEC Table 220.55, for 20 electric ranges, the demand factor is 25 kW plus 1 kW for each range exceeding 12 ranges. Therefore, 25 kW + (20-12) ranges * 1 kW/range = 25 kW + 8 kW = 33 kW. Wait, the table actually specifies 25 kW + 1 kW for each range over 12 for ranges rated over 1.75 kW. And for 20 ranges, Column C (for ranges 8.75 kW and over) is 25 kW + 1 kW for each range over 12. Let's recheck the table. For 20 ranges, Column C is 35 kW. My mistake in interpreting the table. The correct value from NEC Table 220.55 for 20 ranges, assuming they are 8 kW, is 35 kW (Column C for 12-27 ranges, not exceeding 12kW nameplate rating).

Why the other options are wrong

  • A. Incorrect. This value is for fewer ranges or an incorrect application of the demand factor.
  • B. Incorrect. This would be the demand for a different number of ranges or an incorrect calculation.
  • D. Incorrect. This value is significantly higher than permitted by the NEC demand factors.

Electric Range Demand Load (Multi-family)

The minimum demand load for electric cooking appliances in multi-family dwellings is determined using NEC Table 220.55, which applies demand factors based on the number and rating of ranges.

  • NEC Table 220.55 is used for dwelling unit electric range demand loads.
  • Demand factors reduce the calculated load based on the number of ranges.
  • Different columns in the table apply based on the range's nameplate rating.

Memory trick: Remember, many ranges mean less individual demand, so check the table for the right 'group' discount!