Journeyman Electrician Exam (NEC)Services, Feeders, and Branch CircuitsEasy

A residential dwelling unit has a total calculated load of 12,500 VA. What is the minimum standard ampere rating for the main overcurrent device, according to NEC 240.6(A)?

  1. A150 Amperes
  2. B100 Amperes
  3. C60 Amperes
  4. D125 Amperes
Show answer & explanation

Correct answer: B. 100 Amperes

For a dwelling unit with a calculated load of 12,500 VA, the minimum service disconnecting means rating is 100 amperes, as per NEC 230.79(C). NEC 240.6(A) lists standard ampere ratings for overcurrent devices. A 100A main breaker is the smallest standard rating meeting this requirement.

Why the other options are wrong

  • A. 150 Amperes is a standard rating but not the *minimum* required for this load.
  • C. 60 Amperes is too small for a 12,500 VA dwelling unit load.
  • D. 125 Amperes is a standard rating but not the *minimum* required for this load.

Minimum Service Disconnect Rating (Dwelling)

For a one-family dwelling, the service disconnecting means must have a rating of not less than 100 amperes, 3-wire, for a calculated load of 10 kVA or more.

  • Applies to one-family dwellings.
  • Minimum 100A, 3-wire.
  • Triggered by calculated load of 10 kVA (10,000 VA) or more.

Memory trick: Home's main power needs a hundred-amp hero.