CSLB C-36 Plumbing ContractorRough-in PlumbingMedium

A plumbing inspector is reviewing the rough-in for a new residential DWV system. The inspector observes a horizontal wet vent serving a lavatory and a shower. The wet vent pipe diameter is 2 inches. What is the maximum developed length permitted for this 2-inch horizontal wet vent?

  1. A10 feet
  2. B6 feet
  3. C8 feet
  4. D4 feet
Show answer & explanation

Correct answer: B. 6 feet

According to the California Plumbing Code (CPC), a 2-inch horizontal wet vent serving a lavatory and a shower has a maximum developed length of 6 feet. The developed length limitation for wet vents depends on the pipe size and the fixtures served.

Why the other options are wrong

  • A. This length is generally too long for a 2-inch horizontal wet vent.
  • C. This length is generally too long for a 2-inch horizontal wet vent.
  • D. This is typically the maximum developed length for a 1 1/2-inch horizontal wet vent.

Horizontal Wet Vent Length

The maximum developed length allowed for a horizontal pipe that serves as both a drain and a vent.

  • Prevents trap seal loss due to siphoning or backpressure.
  • Length limits depend on pipe size and connected fixture units.
  • Critical for proper DWV system function.

Memory trick: Wet vents are dual-purpose, so don't stretch their limits too far.