CSLB C-36 Plumbing ContractorRough-in PlumbingMedium

A plumbing contractor is installing a new residential gas piping system. The gas meter is located on the exterior of the building. The piping from the meter to the first appliance shut-off valve is 1-inch Schedule 40 black steel pipe. What is the maximum allowable unsupported horizontal length for this 1-inch pipe, according to the California Plumbing Code (CPC)?

  1. A10 feet
  2. B12 feet
  3. C8 feet
  4. D15 feet
Show answer & explanation

Correct answer: A. 10 feet

The California Plumbing Code specifies maximum unsupported lengths for gas piping to prevent sagging and stress on joints. For 1-inch Schedule 40 black steel pipe, the maximum allowable unsupported horizontal length is 10 feet.

Why the other options are wrong

  • B. 12 feet is the limit for 1 1/4-inch pipe, not 1-inch.
  • C. 8 feet is the limit for 3/4-inch pipe, not 1-inch.
  • D. 15 feet is the limit for 1 1/2-inch pipe, not 1-inch.

Gas Pipe Unsupported Length (Horizontal)

The maximum distance a horizontal gas pipe can extend between hangers or supports without sagging or placing undue stress on connections.

  • Prevents pipe damage and leaks.
  • Varies by pipe material, size, and orientation.
  • Specified in the California Plumbing Code (CPC).

Memory trick: Gas Pipes Get Good Support.

More Rough-in Plumbing questions