CSLB C-36 Plumbing ContractorRough-in PlumbingHard

A plumbing inspector is reviewing the rough-in for a new residential DWV system. The inspector notes that a horizontal wet vent serves a lavatory and a shower. What is the maximum developed length permitted for the wet vent from the furthest fixture trap weir to the vent stack or stack vent?

  1. A12 feet
  2. B8 feet
  3. C6 feet
  4. D10 feet
Show answer & explanation

Correct answer: C. 6 feet

The California Plumbing Code (CPC) limits the developed length of horizontal wet vents to prevent excessive pressure fluctuations and ensure proper venting. For a 2-inch wet vent (typical for lavatory and shower), the maximum developed length is 6 feet from the furthest trap weir to the connection to a vent stack or stack vent.

Why the other options are wrong

  • A. 12 feet is incorrect and far exceeds the code limit for a horizontal wet vent.
  • B. 8 feet is incorrect and exceeds the code limit for this scenario.
  • D. 10 feet is incorrect and significantly exceeds the code limit.

Horizontal Wet Vent Length

The maximum permissible developed length of a horizontal wet vent pipe from the furthest fixture trap weir to its connection to a dry vent or stack vent.

  • Prevents trap siphonage or backpressure.
  • Length limits vary by pipe size and fixture units.
  • Ensures adequate air circulation in the DWV system.

Memory trick: Wet Vents are Short: 'Six' feet is the 'Secret' for Small Fixtures.