CSLB C-36 Plumbing ContractorRough-in PlumbingMedium

A plumber is preparing to conduct an air test on a new DWV system rough-in. The system consists of 3-inch PVC piping. What is the minimum air pressure that must be maintained in the system for at least 15 minutes during the test?

  1. A3 psi
  2. B2 psi
  3. C5 psi
  4. D10 psi
Show answer & explanation

Correct answer: C. 5 psi

According to the California Plumbing Code (CPC), DWV systems tested with air must be subjected to a minimum pressure of 5 psi for at least 15 minutes. This pressure is sufficient to detect leaks without overstressing the piping system.

Why the other options are wrong

  • A. 3 psi is below the minimum required pressure for an air test.
  • B. 2 psi is generally too low for an effective air test on a DWV system.
  • D. 10 psi is a higher pressure than required and may not be necessary, though it would still reveal leaks.

DWV Air Test

A method of testing a drain, waste, and vent system rough-in using compressed air to detect leaks, typically required before enclosing walls.

  • Alternative to water test, especially in cold climates or when water is unavailable.
  • Requires a pressure gauge and air compressor.
  • Code specifies minimum pressure and duration.

Memory trick: DWV air test, put it to the stress, 5 psi, 15 minutes, put leaks to the test.