CSLB C-36 Plumbing ContractorRough-in PlumbingMedium

A plumbing inspector is reviewing a rough-in installation for a new gas piping system in a residential garage. The inspector notes that a section of 1-inch diameter black iron gas pipe is unsupported horizontally for a length of 12 feet. According to the UPC, what is the maximum unsupported horizontal length permitted for this pipe size?

  1. A12 feet
  2. B8 feet
  3. C10 feet
  4. D14 feet
Show answer & explanation

Correct answer: C. 10 feet

The Uniform Plumbing Code (UPC) specifies maximum unsupported horizontal lengths for gas piping to prevent sagging and ensure system integrity. For 1-inch nominal diameter black iron pipe, the maximum unsupported length is 10 feet.

Why the other options are wrong

  • A. 12 feet exceeds the maximum permitted unsupported length for 1-inch gas pipe, making the observed installation non-compliant.
  • B. This is the maximum unsupported length for 3/4-inch gas pipe, not 1-inch.
  • D. This length is generally too long and not permitted for 1-inch gas pipe.

Gas Pipe Horizontal Support

The maximum allowable distance between supports for horizontal gas piping to prevent sagging, maintain proper slope, and ensure structural stability of the system.

  • Prevents pipe sagging and stress on joints.
  • Support intervals vary by pipe material and diameter.
  • Ensures long-term system integrity.

Memory trick: Gas pipes need 'Steady Stands' to stay strong.