Master Electrician Exam (NEC)Services, Feeders, and Branch CircuitsMedium

A residential kitchen requires a 20A, 120V small-appliance branch circuit. How many such circuits are required by the NEC for the kitchen area, excluding circuits for specific appliances like refrigerators or dishwashers?

  1. AFour
  2. BThree
  3. CTwo
  4. DOne
Show answer & explanation

Correct answer: C. Two

According to NEC 210.52(B)(1) and 210.11(C)(1), a minimum of two 20-ampere small-appliance branch circuits are required to serve the receptacle outlets specified by 210.52(B)(1) in the kitchen and dining areas of a dwelling unit. These circuits are dedicated to small appliances and cannot serve other loads.

Why the other options are wrong

  • A. While four or more circuits could be installed, two is the minimum requirement.
  • B. While three or more circuits could be installed, two is the minimum requirement.
  • D. One small-appliance branch circuit is insufficient; NEC requires a minimum of two.

Dwelling Unit Small-Appliance Branch Circuits

A minimum of two 20-ampere small-appliance branch circuits are required by the NEC to serve the kitchen, pantry, dining room, breakfast room, and similar areas of a dwelling unit, specifically for receptacle outlets.

  • Minimum of two 20A circuits.
  • Serves kitchen, pantry, dining, breakfast rooms.
  • Cannot serve other outlets or permanently connected luminaires (with exceptions).
  • Mandated by NEC 210.11(C)(1) and 210.52(B)(1).

Memory trick: Kitchen's Core: Two 20A circuits for small appliances, always on their own.