Residential Building Inspector B1Building Planning and Life SafetyMedium

A builder is constructing a new detached garage on a property. The garage will be located 3 feet from the residential dwelling on the same lot. What is the minimum fire-resistance rating required for the exterior wall of the garage that faces the dwelling?

  1. A0-hour fire-resistance rating
  2. B1/2-hour fire-resistance rating
  3. C1-hour fire-resistance rating
  4. D2-hour fire-resistance rating
Show answer & explanation

Correct answer: C. 1-hour fire-resistance rating

According to the 2021 IRC, Table R302.1(1) Exterior Walls, detached garages located less than 5 feet from a dwelling on the same lot are required to have a minimum 1-hour fire-resistance rating for the exterior walls facing the dwelling.

Why the other options are wrong

  • A. 0-hour rating is for walls more than 5 feet from a dwelling or property line.
  • B. 1/2-hour rating is not a standard requirement for this scenario.
  • D. 2-hour rating is typically for more severe exposure conditions or property line proximity.

Fire-Resistance Rating (Garage)

The duration for which a building component, such as a wall, can withstand exposure to fire without failing structurally or allowing fire passage.

  • Depends on the distance to property lines or other structures.
  • Protects adjacent structures from fire spread.
  • Specified in IRC Table R302.1(1).

Memory trick: Distance dictates the fire wall's strength, keeping neighbors safe.