Residential Building Inspector B1Footings and FoundationsEasy

A builder is preparing to pour a concrete slab-on-ground for a new garage. The plans specify a vapor retarder directly beneath the slab. What is the minimum thickness required for this vapor retarder, according to the 2021 IRC?

  1. A15 mil
  2. B10 mil
  3. C6 mil
  4. D3 mil
Show answer & explanation

Correct answer: C. 6 mil

The 2021 IRC, Section R506.2.3, states that a vapor retarder beneath a slab-on-ground shall be a minimum of 6-mil (0.15 mm) polyethylene or approved equivalent.

Why the other options are wrong

  • A. This thickness is not a standard minimum requirement for slab vapor retarders in residential construction.
  • B. While acceptable, this thickness is greater than the minimum required.
  • D. This thickness is generally insufficient for a vapor retarder under a concrete slab.

Slab Vapor Retarder Thickness

The minimum thickness of the vapor retarder material placed directly beneath a concrete slab-on-ground.

  • IRC R506.2.3 specifies 6-mil (0.15 mm) polyethylene.
  • Prevents moisture migration from the ground into the slab/structure.
  • Must be continuous and sealed at seams and penetrations.

Memory trick: Slab needs a shield, 6-mil strong, to keep moisture where it belongs.

More Footings and Foundations questions