CSLB C-46 Solar ContractorElectrical and Plumbing CodesHard

A solar contractor is installing a new solar water heating system for a residential application. The system uses a potable water storage tank and includes a temperature and pressure (T&P) relief valve. According to the California Plumbing Code (CPC), the discharge pipe from the T&P relief valve must be installed to allow complete visual inspection of the flow. What is the maximum height above the receptor to which the discharge pipe can terminate?

  1. A6 inches (150 mm)
  2. B4 inches (100 mm)
  3. C8 inches (200 mm)
  4. D2 inches (50 mm)
Show answer & explanation

Correct answer: A. 6 inches (150 mm)

CPC Section 504.6.4 (UPC 504.6.4) specifies that the discharge pipe from a T&P relief valve shall terminate not more than 6 inches (150 mm) above the floor or flood level rim of the receptor, to allow for complete visual inspection of any discharge. This ensures that a leaking or active T&P valve is easily noticeable.

Why the other options are wrong

  • B. 4 inches is too low and not the specified maximum.
  • C. 8 inches is too high and would not meet the code requirement for visual inspection.
  • D. 2 inches is too low and not the specified maximum.

T&P Discharge Pipe Termination Height

CPC Section 504.6.4 mandates that a T&P relief valve discharge pipe terminate not more than 6 inches above the receptor for visual inspection.

  • Ensures early detection of valve activation.
  • Prevents water damage from hidden leaks.
  • Applies to potable water heater systems.

Memory trick: T&P Discharge: Six Inches Max for a Clear View.

More Electrical and Plumbing Codes questions