CSLB C-46 Solar ContractorElectrical and Plumbing CodesHard

A solar contractor is installing a solar thermal system on a residential building. The system includes piping for potable water. According to the Uniform Plumbing Code (UPC) and California Plumbing Code (CPC), what is the minimum required distance that a potable water pipe must be separated from a building drain or sewer pipe?

  1. A3 inches horizontally, 1 inch vertically
  2. B12 inches horizontally, 6 inches vertically
  3. C6 inches horizontally, 2 inches vertically
  4. D18 inches horizontally, 12 inches vertically
Show answer & explanation

Correct answer: C. 6 inches horizontally, 2 inches vertically

The UPC/CPC mandates specific separation distances to prevent contamination of potable water. For potable water pipes running parallel to building drains or sewers, a minimum horizontal separation of 6 inches is required. For potable water pipes crossing above building drains or sewers, a minimum vertical separation of 2 inches is required. This ensures that in the event of a leak in the drain/sewer, contamination of the potable water supply is minimized.

Why the other options are wrong

  • A. These distances are too small and do not meet UPC/CPC requirements.
  • B. These distances are greater than the minimum required but might be used in specific situations; they are not the minimum.
  • D. These distances are significantly greater than the minimum required and would be impractical as a general minimum.

Potable Water & Drain Separation

Minimum separation distances required by UPC/CPC between potable water piping and building drains or sewers to prevent cross-contamination.

  • 6 inches horizontal separation.
  • 2 inches vertical separation (when crossing).
  • Crucial for public health and safety.

Memory trick: Six horizontal, two vertical, keeps your water safe and ethical!