CSLB C-46 Solar ContractorElectrical and Plumbing CodesMedium

A solar contractor is troubleshooting a ground-fault within a PV array's DC wiring. According to NEC Article 690.5, what is the primary function of a ground-fault detection and interruption (GFDI) device in a PV system?

  1. ATo optimize the power output of the PV array.
  2. BTo prevent overcurrents from damaging PV modules.
  3. CTo monitor the voltage and current levels of individual PV strings.
  4. DTo detect and interrupt ground-fault currents to reduce fire and shock hazards.
Show answer & explanation

Correct answer: D. To detect and interrupt ground-fault currents to reduce fire and shock hazards.

NEC Article 690.5 explicitly states that PV systems shall be provided with a ground-fault detection and interruption (GFDI) device. The primary function of this device is to detect ground-fault currents and quickly interrupt the circuit, thereby reducing the risk of fire and electric shock hazards associated with such faults.

Why the other options are wrong

  • A. Power optimization is typically handled by Maximum Power Point Tracking (MPPT) inverters, not GFDI devices.
  • B. Overcurrent protection is handled by fuses or circuit breakers, not primarily by a GFDI device.
  • C. Monitoring is done by system controllers or inverters, not the GFDI device, which is a safety interruption device.

GFDI Device Function (PV)

A safety device required by NEC 690.5 in PV systems to detect ground-fault currents and rapidly de-energize the affected circuit, mitigating fire and shock hazards.

  • Required in PV systems by NEC 690.5.
  • Detects ground-fault currents.
  • Interrupts the circuit to prevent fire and shock.

Memory trick: GFDI: ground faults it will find, and dangers it will bind!