A homeowner installs a new 96% AFUE condensing furnace. During inspection, a technician checks the condensate drain system. Which component is required to prevent flue gases from escaping through the condensate drain line?

  1. AA barometric damper
  2. BA condensate trap
  3. CA backflow preventer
  4. DA check valve
Show answer & explanation

Correct answer: B. A condensate trap

Condensing furnaces produce acidic condensate that must drain through a P-trap style condensate trap. This trap holds a water seal that blocks flue gases (which are under slight positive pressure from the induced-draft blower) from escaping through the drain line into the living space.

Why the other options are wrong

  • A. A barometric damper is used on Category I natural-draft venting, not condensing furnace condensate.
  • C. A backflow preventer is a plumbing device for potable water systems, not condensate drainage.
  • D. A check valve prevents reverse flow in a pipe but does not provide the water seal needed to block gas.

Condensate Trap

A water-seal trap installed in the condensate drain line of condensing furnaces to prevent positive-pressure flue gases from venting through the drain.

  • Required on all Category IV (condensing) furnaces
  • Must be primed with water before startup
  • Failure to install can allow flue gas leakage or drain blockage from soot

Memory trick: No trap, gas escapes — think sink P-trap.