CSLB C-20 HVAC ContractorHeating SystemsMedium

A gas furnace's blower fails to start, causing the heat exchanger to overheat. Which safety control is designed to shut off the burners in this situation?

  1. AFlame rollout switch
  2. BPressure switch
  3. CHigh-limit switch
  4. DDraft inducer relay
Show answer & explanation

Correct answer: C. High-limit switch

The high-limit switch monitors plenum or heat exchanger temperature and opens to shut off the gas valve if temperatures exceed a safe threshold, such as when blower failure prevents adequate airflow across the heat exchanger.

Why the other options are wrong

  • A. A flame rollout switch detects flames escaping the burner compartment, not general overheating.
  • B. A pressure switch verifies draft inducer operation before ignition, unrelated to overheating.
  • D. A draft inducer relay controls inducer motor power, not temperature safety.

High-Limit Switch

A bimetal safety switch that senses supply plenum temperature and shuts off the gas valve if the furnace overheats due to restricted airflow.

  • Located in the supply air plenum near the heat exchanger
  • Auto-resets once temperature drops to safe range
  • Prevents heat exchanger damage from blower failure or dirty filters

Memory trick: Too hot? High-limit shuts it down.