CSLB General Building (B)Mechanical, Electrical, Plumbing CoordinationHard

A three-story custom home has a continuous combustible soffit and cornice running the full length of the exterior wall. Per fire blocking requirements, concealed spaces behind such combustible construction must be blocked at intervals not exceeding:

  1. A30 feet
  2. B20 feet
  3. C10 feet
  4. D40 feet
Show answer & explanation

Correct answer: B. 20 feet

Concealed spaces behind combustible cornices and soffits must be fire blocked at maximum 20-foot intervals to interrupt fire travel along the length of continuous concealed horizontal spaces.

Why the other options are wrong

  • A. 30 feet exceeds the maximum allowable spacing for this concealed horizontal space.
  • C. 10 feet is the vertical stud cavity requirement, not the cornice/soffit interval.
  • D. 40 feet is far beyond the code-required maximum interval.

Cornice/Soffit Fire Blocking

Concealed spaces behind combustible cornices and soffits require fire blocking at maximum 20-foot intervals to limit horizontal fire spread.

  • Separate requirement from the 10-foot vertical stud cavity rule
  • Applies to continuous horizontal concealed spaces at eaves
  • Prevents fire from running unchecked along roof edges

Memory trick: Twenty feet along the eave, keeps the fire well-behaved.