CSLB General Building (B)Mechanical, Electrical, Plumbing CoordinationMedium

A contractor is comparing draft stopping to fire blocking. Which statement correctly distinguishes the two?

  1. ADraft stopping and fire blocking are interchangeable terms for the same requirement
  2. BFire blocking seals small concealed spaces like stud cavities; draft stopping subdivides larger concealed spaces such as attics and floor/ceiling assemblies
  3. CDraft stopping is used only in exterior walls; fire blocking is used only in interior walls
  4. DFire blocking is required only in commercial buildings; draft stopping is required only in residential buildings
Show answer & explanation

Correct answer: B. Fire blocking seals small concealed spaces like stud cavities; draft stopping subdivides larger concealed spaces such as attics and floor/ceiling assemblies

Fire blocking closes small concealed cavities (stud walls, floor/ceiling junctions), while draft stopping subdivides larger concealed spaces, such as attics exceeding a certain area, to slow fire and smoke spread across large hidden volumes.

Why the other options are wrong

  • A. They serve related but distinct code purposes and are not interchangeable.
  • C. Both apply to interior concealed spaces, not strictly exterior vs interior walls.
  • D. Both requirements apply in residential construction under the CRC, not split by building type this way.

Fire Blocking vs Draft Stopping

Fire blocking seals small concealed cavities; draft stopping subdivides larger concealed spaces like attics to limit fire and smoke spread.

  • Fire blocking: stud walls, floor/ceiling junctions, stair stringers
  • Draft stopping: large attics and floor/ceiling assemblies over specified area thresholds
  • Both limit unseen fire travel but at different scales

Memory trick: Small gaps get blocked, big attics get stopped.

More Mechanical, Electrical, Plumbing Coordination questions