CSLB C-39 Roofing ContractorLow-Slope RoofingMedium

An inspector is checking a termination bar securing the top edge of a mechanically attached TPO membrane at a wall termination. Per typical manufacturer specifications, fasteners in the termination bar should be spaced no more than how far apart on center?

  1. A24 inches
  2. B3 inches
  3. C12 inches
  4. D6 inches
Show answer & explanation

Correct answer: C. 12 inches

Standard single-ply manufacturer specifications typically require termination bar fasteners spaced at a maximum of 12 inches on center to provide adequate holding power and prevent membrane pull-out at wall terminations, with tighter spacing at corners.

Why the other options are wrong

  • A. 24 inches spacing is too wide and would risk membrane pull-out under wind load.
  • B. 3 inches is far tighter than standard field spacing requirements.
  • D. 6 inches is sometimes used at corners but is not the typical field maximum.

Termination Bar Fastening

A metal bar mechanically fastened over the top edge of single-ply membrane at wall or curb terminations to secure and seal the membrane edge, typically fastened at 12 inches on center maximum.

  • Standard max spacing is 12 inches on center
  • Tighter spacing (6 inches) often required at corners
  • Sealant is applied above the bar to prevent water intrusion

Memory trick: A foot apart keeps the membrane from tearing off the wall.

More Low-Slope Roofing questions