A technician measures return air entering the evaporator coil at 75°F and supply air leaving the coil at 55°F on a properly operating split system. What does this 20°F temperature split indicate?

  1. AThe evaporator coil is frozen due to overcharge
  2. BThe system is undercharged with restricted airflow
  3. CThe system is operating normally within the typical delta T range
  4. DThe compressor is not pumping efficiently
Show answer & explanation

Correct answer: C. The system is operating normally within the typical delta T range

A properly functioning residential AC system typically produces a temperature drop of 16–22°F across the evaporator coil under normal indoor conditions. A 20°F split falls within this normal range, indicating correct airflow and charge.

Why the other options are wrong

  • A. A frozen coil typically results from low airflow or undercharge, not indicated by a normal split.
  • B. Undercharge or restricted airflow usually produces a split higher than 22°F, not a normal reading.
  • D. A weak compressor would produce a smaller, not normal, temperature split.

Evaporator Delta T

The temperature drop between return air and supply air across the evaporator coil, used as a quick diagnostic indicator of system performance.

  • Normal split range is about 16–22°F
  • Depends on indoor humidity and airflow (CFM per ton)
  • Abnormal splits point to airflow, charge, or coil problems

Memory trick: Twenty degrees means 'twenty-twenty' airflow vision — system's fine!