CSLB C-20 HVAC ContractorCooling and RefrigerationHard

A residential compressor repeatedly shuts off on a safety control and immediately restarts within seconds, causing high inrush current each time. What component should a technician install to prevent this damaging short-cycling?

  1. AHard start capacitor
  2. BAnti-short-cycle timer (time-delay relay)
  3. CLow-pressure switch
  4. DCrankcase heater
Show answer & explanation

Correct answer: B. Anti-short-cycle timer (time-delay relay)

An anti-short-cycle timer (time-delay relay) prevents the compressor from restarting for a set period (typically 3–5 minutes) after shutdown, allowing system pressures to equalize and the motor windings to cool, thereby preventing damaging repeated inrush currents. The other components address different issues: crankcase heaters prevent refrigerant migration into the oil, low-pressure switches protect against low suction pressure, and hard start capacitors assist compressor startup torque.

Why the other options are wrong

  • A. A hard start capacitor helps overcome starting torque but does nothing to delay restart timing.
  • C. A low-pressure switch is a safety control, but it doesn't prevent rapid restart cycling on its own.
  • D. Crankcase heaters prevent liquid refrigerant migration into the oil sump, not short cycling.

Anti-Short-Cycle Timer

A time-delay relay that prevents a compressor from restarting for several minutes after shutdown, protecting it from damaging inrush current and pressure imbalance.

  • Typical delay: 3-5 minutes after any shutdown
  • Prevents motor winding damage from rapid on/off cycling
  • Distinct from crankcase heaters and hard start kits, which solve different problems

Memory trick: Short cycling? Slow it down with a Timer