Residential Building Inspector B1Wall Construction and Wall CoveringsHard

An inspector is reviewing a residential renovation project where a new interior non-load-bearing wall is being constructed. The wall will enclose a shaft for plumbing pipes extending from the basement through the second floor. What is the minimum fire-resistance rating required for this shaft wall where it passes through the floor assembly?

  1. A1/2 hour
  2. B1 hour
  3. C2 hours
  4. DNo rating required for non-load-bearing shafts
Show answer & explanation

Correct answer: B. 1 hour

According to IRC Section R302.5.1, shafts that extend through more than one story and are not contained within a dwelling unit must be enclosed with fire-resistance-rated construction. A minimum 1-hour fire-resistance rating is required, even for non-load-bearing shafts, to prevent vertical fire spread.

Why the other options are wrong

  • A. 1/2 hour is generally insufficient for shaft enclosures spanning multiple stories.
  • C. 2 hours is typically required for higher-risk scenarios or specific occupancy types, exceeding the minimum for a residential plumbing shaft.
  • D. A fire-resistance rating is required for shafts penetrating multiple floor levels to prevent vertical fire spread, regardless of load-bearing status.

Shaft Wall Fire-Resistance Rating

Shaft walls enclosing plumbing or other penetrations that extend through more than one story in a residential building must have a minimum 1-hour fire-resistance rating.

  • Applies to shafts not contained within a single dwelling unit.
  • Prevents vertical fire and smoke spread.
  • Rating is for the enclosure, not individual pipes.

Memory trick: A multi-story shaft needs 'One Hour' of fire resistance to protect the home.