A builder is constructing a two-story residence with a wall height of 9 feet for each story. What is the maximum spacing permitted for 2x6 wood studs in an exterior load-bearing wall supporting a roof and one floor?

  1. A24 inches on center
  2. B16 inches on center
  3. C48 inches on center
  4. D32 inches on center
Show answer & explanation

Correct answer: A. 24 inches on center

According to IRC Table R602.3(1) for wood stud walls, for a 2x6 exterior load-bearing wall supporting a roof and one floor, the maximum stud spacing is 24 inches on center, provided the wall height does not exceed 10 feet.

Why the other options are wrong

  • B. 16 inches o.c. is permitted for 2x6 studs but is not the maximum allowed for this load condition, making it a more conservative but not required choice.
  • C. 48 inches o.c. is far too wide for any standard wood stud load-bearing wall in residential construction.
  • D. 32 inches o.c. is not permitted for 2x6 exterior load-bearing walls supporting a roof and one floor.

Wood Stud Spacing (Load-Bearing)

The maximum spacing for wood studs in load-bearing walls depends on the stud size, the number of stories supported, and the wall height.

  • 2x4 studs: Max 16 inches o.c. for 1-story or 2-story with roof only.
  • 2x6 studs: Max 24 inches o.c. for 2-story with roof and one floor.
  • Wall height limitations apply to each spacing/size combination.

Memory trick: Studs are like legs holding up the house, more weight or height means closer legs.