Commercial Building Inspector B2Wall Construction and Wall CoveringsEasy

A commercial building inspector is reviewing the design for a 4-story Type II-A commercial building. The exterior walls are designed as non-bearing fire-resistance-rated walls. What is the minimum fire-resistance rating required for these exterior walls if the fire separation distance is 15 feet (4572 mm)?

  1. A1 hour
  2. B0 hours
  3. C3 hours
  4. D2 hours
Show answer & explanation

Correct answer: A. 1 hour

For a Type II-A construction, exterior non-bearing walls with a fire separation distance of 11 feet to 30 feet (3353 mm to 9144 mm) require a minimum 1-hour fire-resistance rating.

Why the other options are wrong

  • B. 0 hours is typically for greater fire separation distances or specific circumstances, not applicable here.
  • C. 3-hour rating is generally for higher hazard occupancies or larger buildings, not applicable here.
  • D. 2-hour rating is required for bearing walls or smaller fire separation distances in Type II-A.

Exterior Wall Fire Rating (Type II-A)

The minimum fire-resistance rating required for exterior non-bearing walls in Type II-A construction, based on fire separation distance.

  • Type II-A construction has a higher fire-resistance requirement than Type II-B.
  • Fire separation distance dictates the required rating.
  • Non-bearing walls have different requirements than bearing walls.

Memory trick: Fire walls protect, distance dictates, type defines.