Commercial Building Inspector B2Wall Construction and Wall CoveringsHard

An inspector is checking the installation of a fire door assembly in a 1-hour fire-resistance-rated corridor wall. The door is a single-panel, swinging fire door. What is the minimum hourly fire protection rating required for this fire door assembly?

  1. A45 minutes
  2. B1 hour
  3. C20 minutes
  4. D30 minutes
Show answer & explanation

Correct answer: A. 45 minutes

According to IBC Table 716.1.1(1), for openings in 1-hour fire-resistance-rated corridor walls, the minimum required fire protection rating for a fire door assembly is 45 minutes.

Why the other options are wrong

  • B. 1 hour would match the wall rating but is not the minimum required for a corridor wall in this scenario; 45 minutes is permissible.
  • C. 20 minutes is typically for smoke barrier doors or specific room doors, not 1-hour rated corridor walls.
  • D. 30 minutes is not a standard fire door rating for 1-hour rated corridor walls.

Fire Door Rating (Corridor Wall)

Fire door assemblies in fire-resistance-rated corridor walls have specific fire protection ratings, which are often less than the wall's rating, but sufficient to maintain compartmentalization and egress.

  • Ratings are found in IBC Table 716.1.1(1).
  • Corridor doors often have lower ratings than the wall.
  • Ensures safe passage during a fire.

Memory trick: Door's Defense: Corridor's Crucial Code.