Residential Building Inspector B1Roof-Ceiling ConstructionMedium

A residential building inspector is reviewing the installation of roof sheathing. The roof rafters are spaced 24 inches on center. What is the minimum nominal thickness of plywood sheathing required for a roof with this rafter spacing, assuming the sheathing is applied with the long dimension perpendicular to the rafters?

  1. A3/4 inch (19.1 mm)
  2. B5/8 inch (15.9 mm)
  3. C1/2 inch (12.7 mm)
  4. D3/8 inch (9.5 mm)
Show answer & explanation

Correct answer: C. 1/2 inch (12.7 mm)

For rafters spaced 24 inches on center, the minimum nominal thickness for plywood roof sheathing, when applied with the long dimension perpendicular to the rafters, is 1/2 inch (12.7 mm) according to IRC tables for wood structural panel sheathing.

Why the other options are wrong

  • A. 3/4 inch is thicker than required for this spacing and would be over-specification.
  • B. 5/8 inch would be acceptable but is not the minimum required.
  • D. 3/8 inch is typically for 16-inch on center spacing or less.

Roof Sheathing Thickness

The minimum required thickness of wood structural panel roof sheathing is determined by the spacing of the supporting rafters or trusses.

  • Plywood and OSB panels have specific span ratings.
  • Long dimension perpendicular to supports is the typical installation method.
  • Thicker sheathing is required for wider rafter spacing.

Memory trick: Sheathing thickness depends on how far the rafters spread.