Residential Building Inspector B1Roof-Ceiling ConstructionMedium

An inspector is reviewing plans for a residential roof. The plans indicate the use of asphalt shingles on a roof with a pitch of 2:12. What is the minimum required underlayment for this roof pitch according to the IRC?

  1. AOne layer of No. 30 felt
  2. BTwo layers of No. 15 felt or one layer of No. 30 felt
  3. COne layer of No. 15 felt
  4. DSelf-adhering polymer modified bitumen sheet
Show answer & explanation

Correct answer: B. Two layers of No. 15 felt or one layer of No. 30 felt

For roof slopes between 2:12 and 4:12, the IRC requires a double-layer underlayment or an equivalent self-adhering membrane. Two layers of No. 15 felt or one layer of No. 30 felt satisfy this requirement.

Why the other options are wrong

  • A. One layer of No. 30 felt is equivalent to two layers of No. 15 felt, but the question implies a minimum, and two layers of No. 15 felt is a common method.
  • C. One layer of No. 15 felt is typically for slopes 4:12 and greater.
  • D. While a self-adhering membrane is an acceptable alternative, it's not the minimum required felt underlayment.

Low-Slope Asphalt Shingle Underlayment

For asphalt shingle roofs with a slope between 2:12 and 4:12, a specific underlayment system is required to prevent water penetration due to reduced drainage.

  • Applies to slopes 2:12 up to less than 4:12.
  • Requires two layers of underlayment felt.
  • Common options are two layers of No. 15 felt or one layer of No. 30 felt.

Memory trick: Slopes need protection, especially when they're low and slow.

More Roof-Ceiling Construction questions