Commercial Building Inspector B2Roof Ceiling ConstructionMedium

A client is planning to construct a new commercial building with a roof assembly utilizing steel open-web joists. The roof is required to have a 1-hour fire-resistance rating. What is the typical minimum thickness of sprayed fire-resistant material (SFRM) required for steel joists to achieve a 1-hour rating, assuming a standard density SFRM and typical joist sizes?

  1. A1 1/4 inches
  2. B1/2 inch
  3. C1 inch
  4. D3/4 inch
Show answer & explanation

Correct answer: D. 3/4 inch

For steel open-web joists requiring a 1-hour fire-resistance rating, a typical minimum thickness of 3/4 inch of sprayed fire-resistant material (SFRM) is often specified. Actual requirements can vary based on specific joist dimensions, SFRM density, and tested fire-rated assemblies.

Why the other options are wrong

  • A. 1 1/4 inches is likely for higher fire-resistance ratings (e.g., 2 hours) or larger/heavier steel members.
  • B. 1/2 inch is generally insufficient for a 1-hour rating on steel joists.
  • C. 1 inch would provide a higher rating or margin of safety, but is not the typical minimum for 1 hour.

SFRM Thickness for 1-Hour Rating

The minimum thickness of sprayed fire-resistant material (SFRM) applied to steel structural members to achieve a 1-hour fire-resistance rating, typically 3/4 inch.

  • Protects steel from high temperatures.
  • Thickness varies by rating and steel member size.
  • Must be applied per tested assembly designs.

Memory trick: Steel needs a shield, fire's heat it must yield. 3/4 inch is the minimum for a 1-hour field.