Residential Building Inspector B1Footings and FoundationsMedium

A building inspector is examining the foundation of a new residential structure. The foundation drain is installed with a perforated pipe. What is the minimum required diameter for this perforated pipe, according to the 2021 IRC?

  1. A3 inches (76 mm)
  2. B4 inches (102 mm)
  3. C6 inches (152 mm)
  4. D2 inches (51 mm)
Show answer & explanation

Correct answer: B. 4 inches (102 mm)

IRC Section R405.1 specifies that perforated pipe used for foundation drains shall be not less than 4 inches (102 mm) in diameter.

Why the other options are wrong

  • A. While used in some applications, 3 inches is below the minimum required for a foundation drain.
  • C. This diameter is larger than the minimum required and would be acceptable, but not the minimum.
  • D. This diameter is too small for a foundation drain and would not be permitted by the IRC.

Foundation Drain Pipe Diameter

The minimum required diameter for perforated pipe used as a foundation drain to collect and remove groundwater.

  • IRC R405.1 specifies a minimum of 4 inches (102 mm).
  • Ensures adequate flow capacity for collected water.
  • Pipe must be installed with proper slope and surrounded by gravel.

Memory trick: Drain pipe: four inches wide, keeps the water on the outside.