A pharmacy technician is preparing a sterile IV admixture in a laminar airflow workbench (LAFW). The technician notices a small crack in the workbench's HEPA filter. What is the MOST appropriate immediate action?

  1. AApply sterile tape over the crack until a replacement filter arrives.
  2. BSwitch to a nearby biological safety cabinet (BSC) without further inspection.
  3. CContinue compounding, but work more slowly and carefully.
  4. DImmediately stop all compounding in the LAFW and report the issue.
Show answer & explanation

Correct answer: D. Immediately stop all compounding in the LAFW and report the issue.

A cracked HEPA filter compromises the sterility of the compounding environment. Continuing to compound would risk microbial contamination of sterile products, posing a significant patient safety hazard. All operations must cease, and the issue must be reported for immediate repair or replacement.

Why the other options are wrong

  • A. Sterile tape is not an effective or validated repair for a HEPA filter and does not restore its integrity.
  • B. Switching to another hood without proper assessment of its certification and suitability for the task is not a safe or appropriate primary response.
  • C. Working more slowly does not mitigate the contamination risk from a compromised filter.

HEPA Filter Integrity

The ability of a High-Efficiency Particulate Air (HEPA) filter in a cleanroom or workbench to effectively remove airborne particles, ensuring a sterile environment.

  • Critical for sterile compounding.
  • Damage compromises sterility.
  • Requires immediate action if integrity is breached.

Memory trick: HEPA Hole? Halt, Hand Over, Help!