Journeyman Plumber ExamDrainage, Waste, and Venting (DWV) SystemsEasy

A plumber is installing a P-trap for a kitchen sink. What is the minimum trap seal depth typically required by plumbing codes?

  1. A1 inch (25 mm)
  2. B3 inches (75 mm)
  3. C2 inches (50 mm)
  4. D4 inches (100 mm)
Show answer & explanation

Correct answer: C. 2 inches (50 mm)

Most plumbing codes specify a minimum trap seal depth of 2 inches (50 mm) and a maximum of 4 inches (100 mm) to ensure an effective water seal against sewer gases while allowing for proper drainage.

Why the other options are wrong

  • A. 1 inch is generally too shallow and could easily be lost due to evaporation or pressure fluctuations.
  • B. 3 inches is within the acceptable range but not the minimum.
  • D. 4 inches is the commonly accepted maximum trap seal depth, not the minimum.

Trap Seal Depth

The vertical distance from the crown weir to the dip of a trap, representing the depth of water that forms the seal.

  • Prevents sewer gas entry.
  • Must be maintained for effective operation.
  • Minimum and maximum depths are code-regulated.

Memory trick: A P-trap's seal, a smelly deal, ensures gas won't feel so real!