Journeyman Plumber ExamDrainage, Waste, and Venting (DWV) SystemsMedium

A plumber is installing a battery of three lavatories, each with a 1 1/2-inch trap, connected to a horizontal branch drain. The branch drain is 15 feet long. What is the minimum required size for the vent pipe serving this branch?

  1. A1 1/4 inches
  2. B3 inches
  3. C2 inches
  4. D1 1/2 inches
Show answer & explanation

Correct answer: D. 1 1/2 inches

According to plumbing codes, the minimum size of a vent pipe for a branch drain is generally half the diameter of the drain pipe it serves, but not less than 1 1/4 inches. For a 1 1/2-inch branch, a 1 1/2-inch vent is required.

Why the other options are wrong

  • A. 1 1/4 inches is the absolute minimum for any vent, but not sufficient for a 1 1/2-inch or larger branch.
  • B. 3 inches is excessively large for venting this setup.
  • C. 2 inches would be acceptable but is larger than the minimum required.

Branch Vent Sizing (Minimum)

The smallest allowable diameter for a vent pipe serving a horizontal branch drain, determined by the size of the drain it protects.

  • Vent size must be at least half the drain size.
  • Absolute minimum vent size is typically 1 1/4 inches.
  • Ensures proper air circulation and prevents trap siphoning.

Memory trick: Vent's Verdict: Half the Drain, Never Less.