Journeyman Plumber ExamDrainage, Waste, and Venting (DWV) SystemsMedium

A plumber is installing a fixture trap for a dishwasher that discharges into a standpipe. What is the maximum developed length from the trap weir to the vent fitting?

  1. A4 feet
  2. B2 feet
  3. C5 feet
  4. D3 feet
Show answer & explanation

Correct answer: D. 3 feet

For a standard 1 1/2-inch fixture trap, the maximum developed length from the trap weir to the vent fitting is 3 feet 6 inches (42 inches). Therefore, 3 feet is the closest and most appropriate answer among the options.

Why the other options are wrong

  • A. This exceeds the maximum developed length for a 1 1/2-inch fixture trap arm.
  • B. This is too short for a typical 1 1/2-inch fixture trap arm developed length.
  • C. This significantly exceeds the maximum developed length for a 1 1/2-inch fixture trap arm.

Fixture Trap Arm Developed Length

The developed length of a fixture trap arm is the total length of the drainage pipe from the trap weir to the vent pipe fitting, measured along the centerline of the pipe.

  • Prevents trap siphonage.
  • Length varies by trap/pipe size.
  • Typically 3'6" for 1 1/2" pipe.
  • Prevents excessive pressure fluctuations.

Memory trick: Trap Arms Must Be Short Enough to Vent, Long Enough to Connect.