Journeyman Plumber ExamDrainage, Waste, and Venting (DWV) SystemsMedium

A plumber is installing a new 4-inch building drain that will serve a total of 150 drainage fixture units (DFUs) and has a slope of 1/8 inch per foot. According to plumbing codes, what is the maximum permissible DFU load for this pipe?

  1. A250 DFUs
  2. B384 DFUs
  3. C180 DFUs
  4. D216 DFUs
Show answer & explanation

Correct answer: D. 216 DFUs

For a 4-inch building drain with a slope of 1/8 inch per foot, the maximum DFU load allowed by most plumbing codes is 216 DFUs. The proposed 150 DFUs falls within this limit.

Why the other options are wrong

  • A. 250 DFUs is too high for a 4-inch drain at this slope; it might be for a larger pipe or steeper slope.
  • B. 384 DFUs is the maximum for a 4-inch drain at 1/4 inch per foot slope, not 1/8 inch per foot.
  • C. 180 DFUs is typically the maximum for a 4-inch drain at 1/4 inch per foot slope, not 1/8 inch per foot.

Building Drain Sizing (DFU & Slope)

The process of determining the minimum required diameter for a building drain based on the total drainage fixture units (DFUs) it serves and its installed slope.

  • DFU load increases with more fixtures.
  • Steeper slopes (e.g., 1/4 inch/foot) generally allow for higher DFU capacity than shallower slopes (e.g., 1/8 inch/foot) for the same pipe size.
  • Referencing plumbing code tables is essential for accurate sizing.

Memory trick: Slope and Size are the twin keys to DFU capacity's maze.