Journeyman Plumber ExamDrainage, Waste, and Venting (DWV) SystemsEasy

A plumber is installing a floor sink that receives discharge from a commercial ice machine. This discharge must not directly connect to the sanitary drainage system. What type of waste connection is required?

  1. ASpecial waste
  2. BIndirect waste
  3. CDirect waste
  4. DCombination waste
Show answer & explanation

Correct answer: B. Indirect waste

An indirect waste connection, typically involving an air gap or air break, is required for fixtures and equipment that discharge contaminated liquids or liquids that could pose a cross-connection hazard, such as condensate from ice machines, refrigerators, or sterilizers.

Why the other options are wrong

  • A. Special waste refers to the type of waste (e.g., chemical, radioactive) rather than the connection method.
  • C. Direct waste connects directly to the sanitary drainage system, which is prohibited for ice machines due to cross-connection risk.
  • D. Combination waste refers to a pipe that serves as both a drain and a vent, not a specific connection type for protected fixtures.

Indirect Waste

An indirect waste is a drainage pipe that discharges into a plumbing fixture, receptor, or interceptor that is not an integral part of the building drainage system. It provides an air gap or air break to prevent cross-contamination.

  • Prevents cross-contamination.
  • Uses air gap or air break.
  • Required for food/beverage equipment.
  • Required for medical/dental equipment.

Memory trick: Indirect Means No Direct Link, Avoiding Contamination, We Think!