Journeyman Plumber ExamDrainage, Waste, and Venting (DWV) SystemsEasy

A plumber is inspecting a newly installed DWV system before final cover. What is the minimum required test pressure for an air test on the drainage portion of the system?

  1. A5 psi (34.5 kPa)
  2. B3 psi (20.7 kPa)
  3. C10 psi (68.9 kPa)
  4. D2 psi (13.8 kPa)
Show answer & explanation

Correct answer: A. 5 psi (34.5 kPa)

Most plumbing codes require a minimum air test pressure of 5 psi (34.5 kPa) for the drainage and vent system, held for a specified duration, typically 15 minutes, without loss.

Why the other options are wrong

  • B. While closer, 3 psi is typically below the minimum required pressure for an air test.
  • C. 10 psi is usually higher than required and could potentially stress the system unnecessarily, though it would certainly reveal leaks.
  • D. This pressure is generally too low to adequately test for leaks in a DWV system.

DWV Air Test

A method of testing the integrity of a drainage, waste, and vent system by pressurizing it with air and observing for pressure loss.

  • Detects leaks in pipes and fittings.
  • Requires all openings to be sealed.
  • Typically held for 15 minutes without pressure drop.

Memory trick: Pressure checks are key, for a leak-free guarantee!