Journeyman Plumber ExamDrainage, Waste, and Venting (DWV) SystemsMedium

A plumber is installing a new residential DWV system. The main building drain connects to the public sewer at the property line. What is the minimum size, in inches, required for a cleanout installed at the junction of the building drain and the building sewer?

  1. A4 inches
  2. B2 inches
  3. C6 inches
  4. D3 inches
Show answer & explanation

Correct answer: A. 4 inches

According to most plumbing codes, a cleanout at the junction of the building drain and building sewer must be at least as large as the pipe it serves, but not less than 4 inches in diameter.

Why the other options are wrong

  • B. This size is typically too small for a main building drain/sewer cleanout.
  • C. While a 6-inch cleanout would be acceptable, it is not the minimum required size for this specific location if the pipe is smaller.
  • D. While a 3-inch drain might exist, the cleanout at this critical junction must be larger.

Building Drain/Sewer Cleanout Size

The minimum diameter required for a cleanout located at the critical junction between a building's internal drainage system and the external sewer connection.

  • Must be at least the size of the pipe served.
  • Minimum 4 inches at building drain/sewer junction.
  • Ensures adequate access for clearing blockages.

Memory trick: Main drain, main access, four inches or more.

More Drainage, Waste, and Venting (DWV) Systems questions