Journeyman Plumber ExamDrainage, Waste, and Venting (DWV) SystemsMedium

A plumber is installing a battery of four lavatories in a public restroom. Each lavatory has a 1 1/4-inch trap and discharges into a 2-inch horizontal branch drain. What is the maximum developed length allowed for the trap arm of each lavatory to its vent connection according to common plumbing codes?

  1. A3 feet 6 inches
  2. B5 feet
  3. C2 feet 6 inches
  4. D6 feet
Show answer & explanation

Correct answer: C. 2 feet 6 inches

For a 1 1/4-inch trap, the maximum developed length of the trap arm to its vent connection is typically 2 feet 6 inches (30 inches). This ensures proper venting and prevents trap siphonage.

Why the other options are wrong

  • A. 3 feet 6 inches (42 inches) is too long for a 1 1/4-inch trap arm and could lead to siphonage.
  • B. 5 feet (60 inches) is the maximum developed length for a 2-inch trap arm, not 1 1/4-inch.
  • D. 6 feet is excessively long for a trap arm of this size and is not allowed by code.

Trap Arm Developed Length (1 1/4-inch)

The maximum permissible length of the horizontal pipe connecting a 1 1/4-inch fixture trap to its vent pipe, measured from the trap weir to the vent connection.

  • Prevents trap seal loss due to siphonage or backpressure.
  • Length limit is specific to the trap arm diameter.
  • Measured along the centerline of the pipe.
  • For 1 1/4-inch traps, typically 2 feet 6 inches (30 inches).

Memory trick: Small pipes have short arms, or they'll lose their charm!

More Drainage, Waste, and Venting (DWV) Systems questions