Journeyman Plumber ExamDrainage, Waste, and Venting (DWV) SystemsHard

A plumber is installing a combination waste and vent system for a series of floor drains in a commercial kitchen. This system uses a horizontal wet vent. What is the maximum number of drainage fixture units (DFUs) that a 3-inch horizontal wet vent can serve?

  1. A12 DFUs
  2. B20 DFUs
  3. C36 DFUs
  4. D8 DFUs
Show answer & explanation

Correct answer: B. 20 DFUs

For a horizontal wet vent, the maximum number of DFUs permitted is generally lower than for a dry vent or a vertical wet vent of the same size. A 3-inch horizontal wet vent is typically limited to 20 DFUs.

Why the other options are wrong

  • A. This DFU count is often associated with a 2-inch horizontal wet vent.
  • C. This DFU count is usually for larger pipes or dry vent applications.
  • D. This DFU count is too low for a 3-inch horizontal wet vent.

Horizontal Wet Vent DFU Capacity

The maximum drainage fixture units allowed on a horizontal pipe that serves as both a drainage and vent pipe, subject to specific code limitations.

  • Capacity is reduced compared to dry vents.
  • Specific limits for each pipe size.
  • Critical for proper air circulation and drainage.

Memory trick: Wet vents get weary, carry less load.

More Drainage, Waste, and Venting (DWV) Systems questions