Journeyman Plumber ExamDrainage, Waste, and Venting (DWV) SystemsMedium

A plumber is installing a main vent stack for a 4-story building. The building's main soil stack is 4 inches in diameter. What is the minimum required diameter for this main vent stack?

  1. A5 inches
  2. B2 inches
  3. C4 inches
  4. D3 inches
Show answer & explanation

Correct answer: C. 4 inches

The main vent stack, also known as a vent stack, must be at least the same diameter as the soil or waste stack it serves, or larger. Therefore, for a 4-inch soil stack, the minimum vent stack diameter is 4 inches.

Why the other options are wrong

  • A. 5 inches would be acceptable but is larger than the minimum required.
  • B. 2 inches is too small for a 4-inch soil stack and would lead to inadequate venting.
  • D. 3 inches is too small for a 4-inch soil stack.

Main Vent Stack Sizing

The minimum diameter requirement for the vertical vent pipe that extends through the roof and serves as the primary air inlet/outlet for the DWV system.

  • Must be at least the same size as the largest soil or waste stack.
  • Ensures adequate air flow for the entire system.
  • Prevents siphoning and backpressure.

Memory trick: Stack's Same Size, Skyward Stream.