CSLB General Building (B)Framing and CarpentryHard

A framer notches a top plate 2-1/2 inches deep to run a 2-inch water pipe through a wall where the plate is 3-1/2 inches wide. Since the notch removes more than 50% of the plate's width, what does code require to maintain the wall's structural continuity?

  1. AThe entire top plate must be replaced with a laminated veneer lumber (LVL) member
  2. BThe stud spacing must be reduced to 12 inches on center near the notch
  3. CNothing additional is required if the wall is non-load-bearing
  4. DA minimum 16-gauge, 1-1/2-inch-wide galvanized metal tie must be fastened across the notch
Show answer & explanation

Correct answer: D. A minimum 16-gauge, 1-1/2-inch-wide galvanized metal tie must be fastened across the notch

When a top plate is notched or bored such that more than 50% of its width is removed, code requires a minimum 16-gauge, 1-1/2-inch-wide galvanized metal tie be securely fastened across and beyond the notch on each side to restore load path continuity for both bearing and non-bearing walls.

Why the other options are wrong

  • A. Replacing the entire plate with LVL is unnecessary; a tie plate is the code remedy.
  • B. Reducing stud spacing does not address the discontinuity in the plate itself.
  • C. The tie requirement applies even to non-bearing walls when the notch exceeds 50% of plate width.

Top Plate Notch Metal Tie

When a top plate is notched more than 50% of its width for utilities, a minimum 16-gauge x 1-1/2-inch metal tie must be nailed across the notch to maintain structural continuity.

  • Trigger: notch removes >50% of plate width
  • Remedy: 16-gauge, 1.5-inch galvanized tie plate
  • Applies to both bearing and non-bearing walls per code

Memory trick: Cut past half, bridge with metal.

More Framing and Carpentry questions