CSLB C-20 HVAC ContractorVentilation and Air DistributionEasy

Per the California Mechanical Code, what is the default maximum length of a clothes dryer exhaust duct (measured with two 90-degree elbows), unless a different length is otherwise permitted by the dryer manufacturer's installation instructions or an engineered calculation?

  1. A14 feet
  2. B25 feet
  3. C35 feet
  4. D10 feet
Show answer & explanation

Correct answer: A. 14 feet

The California Mechanical Code sets a default maximum dryer exhaust duct length of 14 feet with two 90-degree elbows, with deductions required for additional elbows, unless the manufacturer's instructions or a code-approved calculation allow a longer run.

Why the other options are wrong

  • B. 25 feet exceeds the default without manufacturer approval or calculation.
  • C. 35 feet is far beyond the default allowance.
  • D. 10 feet is shorter than the code default.

Dryer Exhaust Duct Length

The CMC sets a default maximum clothes dryer exhaust duct length of 14 feet with two 90-degree elbows, with length reductions for additional elbows unless otherwise justified.

  • Default max is 14 feet with two 90° elbows
  • Additional elbows reduce allowable length
  • Manufacturer instructions or engineering calculations can permit longer runs

Memory trick: Fourteen feet, two turns — that's the dryer duct's default rule.

More Ventilation and Air Distribution questions