CSLB C-46 Solar ContractorSafetyMedium

A solar crew is installing modules on a commercial building with a roof height of 25 feet. The roof has a low-slope (less than 4:12 pitch) and the work is being performed within 6 feet of the roof edge. Which of the following fall protection methods is required by Cal/OSHA?

  1. AGuardrail system, safety net system, or personal fall arrest system
  2. BWarning line system with a safety monitor
  3. CNo fall protection is required if workers are experienced
  4. DSafety monitor system only
Show answer & explanation

Correct answer: A. Guardrail system, safety net system, or personal fall arrest system

For low-slope roofs (less than 4:12 pitch) with work performed within 6 feet of the edge, Cal/OSHA requires conventional fall protection methods: guardrail systems, safety net systems, or personal fall arrest systems. Warning line systems with a safety monitor are permitted only when work is performed between 6 and 15 feet from the edge.

Why the other options are wrong

  • B. A warning line system with a safety monitor is typically allowed for work between 6 and 15 feet from the edge, not within 6 feet.
  • C. Experience does not exempt workers from mandatory fall protection requirements.
  • D. Safety monitor system alone is generally not sufficient for work within 6 feet of the edge.

Cal/OSHA Low-Slope Roof Fall Protection (Within 6 ft)

Cal/OSHA requirements for fall protection when working on a low-slope roof (less than 4:12 pitch) within 6 feet of the roof edge.

  • Applies to low-slope roofs (less than 4:12 pitch).
  • Mandates conventional fall protection: guardrails, safety nets, or personal fall arrest systems.
  • Warning lines with safety monitors are not sufficient for this proximity to the edge.

Memory trick: Six feet close, conventional safety you must propose.