Commercial Building Inspector B2General Administration, Permits, and PlansMedium

A commercial building inspector is reviewing plans for a new 4-story Group R-2 apartment building. The building is designed with Type V-A construction. What is the minimum required fire-resistance rating for the interior nonbearing walls?

  1. A0 hours
  2. B0.5 hours
  3. C2 hours
  4. D1 hour
Show answer & explanation

Correct answer: A. 0 hours

For Type V-A construction, IBC Table 601 specifies that interior nonbearing walls are permitted to have a 0-hour fire-resistance rating. This means no specific fire rating is required for these elements unless they form part of a fire barrier or shaft enclosure.

Why the other options are wrong

  • B. 0.5 hours (30 minutes) is not a standard fire-resistance rating for general interior nonbearing walls in IBC.
  • C. 2 hours is for higher-rated elements or construction types, not for interior nonbearing walls in Type V-A.
  • D. 1 hour is required for interior bearing walls, structural frame, and floor/roof construction in Type V-A, but not for nonbearing walls.

Type V-A Interior Nonbearing Wall Rating

In Type V-A construction, interior nonbearing walls generally do not require a specific fire-resistance rating, meaning a 0-hour rating is permitted by the IBC.

  • Type V-A allows combustible materials.
  • Interior nonbearing walls are not critical for structural integrity.
  • Specific ratings apply to bearing walls and floor/roof elements.

Memory trick: Five-A's inside walls can be zero-rated, unless they're holding up the sky.

More General Administration, Permits, and Plans questions