CSLB C-27 Landscaping ContractorIrrigation SystemsMedium

A landscape contractor is performing a spring start-up for an irrigation system that has been winterized. After opening the main shut-off valve, the contractor notices a continuous, low-volume flow of water coming from one of the sprinkler heads in a zone that is currently off. All other zones are functioning correctly. What is the most probable cause of this issue?

  1. AA stuck-open solenoid on the zone valve
  2. BA clogged filter at the main backflow preventer
  3. CInsufficient water pressure in the mainline
  4. DA broken lateral line in that zone
Show answer & explanation

Correct answer: A. A stuck-open solenoid on the zone valve

A continuous low-volume flow from an 'off' zone's sprinkler head typically indicates that the zone valve is not fully closing. This is most often caused by a stuck-open solenoid, which prevents the diaphragm from seating properly, allowing water to trickle through.

Why the other options are wrong

  • B. A clogged filter would reduce pressure to the entire system or downstream zones, not cause a specific zone to leak when off.
  • C. Insufficient pressure would result in poor spray or no pop-up when the zone is on, not a continuous flow when off.
  • D. A broken lateral line would cause a larger leak, usually at the break point, not a continuous low flow from a head.

Stuck-Open Solenoid

A solenoid on an irrigation zone valve that remains energized or mechanically stuck in the open position, preventing the valve diaphragm from seating and causing continuous water flow to the zone.

  • Prevents the valve from closing fully
  • Results in continuous trickle/drip from heads in that zone
  • Can be due to debris, electrical issue, or mechanical failure
  • Requires cleaning, repair, or replacement of the solenoid/valve

Memory trick: Trickle from an off zone? Solenoid's stuck, not letting go.

More Irrigation Systems questions