CDL Air Brakes TestUsing Air BrakesMedium

A commercial driver is performing a pre-trip inspection and notices that the air compressor's automatic shut-off occurs at 125 psi, but it doesn't restart until the pressure drops to 85 psi. What component is likely malfunctioning?

  1. AThe air dryer
  2. BThe governor
  3. CThe safety relief valve
  4. DThe foot valve (brake pedal)
Show answer & explanation

Correct answer: B. The governor

The governor controls when the air compressor starts and stops. Its settings determine the cut-in and cut-out pressures. A wide or incorrect pressure range indicates a potential governor malfunction.

Why the other options are wrong

  • A. The air dryer removes moisture from the air, but doesn't control compressor on/off cycles.
  • C. The safety relief valve protects against over-pressurization but doesn't control the normal operating range.
  • D. The foot valve applies the brakes and releases air from the system, but doesn't regulate compressor operation.

Air Compressor Governor

A component in the air brake system that regulates the air compressor, ensuring it maintains air pressure within a specified operating range by controlling its start and stop points.

  • Controls compressor cut-in and cut-out pressures.
  • Typically cuts out around 125 psi.
  • Typically cuts in around 100 psi.

Memory trick: Governor: 'Controls Compressor's Cycles'

More Using Air Brakes questions