Commercial Building Inspector B2General Administration, Permits, and PlansMedium

A commercial building inspector is reviewing plans for a new 6-story Group B office building. The building will have an automatic sprinkler system throughout. What is the minimum required fire-resistance rating for the structural frame of this Type I-A construction?

  1. A4 hours
  2. B1 hour
  3. C2 hours
  4. D3 hours
Show answer & explanation

Correct answer: D. 3 hours

For Type I-A construction, the IBC specifies a minimum 3-hour fire-resistance rating for the structural frame, regardless of the presence of an automatic sprinkler system, due to its inherent high level of fire protection.

Why the other options are wrong

  • A. 4 hours is reserved for specific elements like exterior bearing walls in Type I-A or higher-risk scenarios.
  • B. 1 hour is typically for lower-rated construction types or non-bearing walls.
  • C. 2 hours is common for Type I-B or Type II-A construction, but not Type I-A structural frames.

Type I-A Construction Structural Frame Rating

Type I-A construction represents the highest level of fire-resistive construction. The structural frame, which includes columns, girders, trusses, and bearing walls, must maintain its structural integrity for a specified duration under fire exposure.

  • Highest fire-resistance classification.
  • Minimum 3-hour rating for structural frame.
  • Automatic sprinklers do not reduce this specific rating.

Memory trick: Imagine a 'Very Secure Structure' (VSS) where I-A means 'Iron Strong' for 3 hours.