EPA Section 608 Universal Certification ExamType I (Small Appliances)Medium

A technician is preparing to recover refrigerant from a small appliance. To prevent the introduction of air into the recovery cylinder during connection, what is the best practice?

  1. AConnect the hoses quickly to minimize air exposure.
  2. BPurge the recovery hoses with nitrogen before connecting them.
  3. CEvacuate the recovery hoses and manifold before opening the cylinder valve.
  4. DVent a small amount of refrigerant from the appliance through the hoses.
Show answer & explanation

Correct answer: C. Evacuate the recovery hoses and manifold before opening the cylinder valve.

Evacuating the recovery hoses and manifold removes any air present in them before recovery begins. This prevents non-condensable gases from being drawn into the recovery cylinder along with the refrigerant, maintaining refrigerant purity.

Why the other options are wrong

  • A. Connecting quickly doesn't remove air already in the hoses; it only limits further ingress.
  • B. Purging with nitrogen can introduce another non-condensable gas if not properly removed.
  • D. Venting refrigerant is illegal and releases harmful substances into the atmosphere.

Preventing Air in Recovery

To prevent non-condensable gases (air) from entering the recovery cylinder, recovery hoses and the manifold gauge set should be evacuated to a vacuum before starting the refrigerant recovery process.

  • Air is a non-condensable gas.
  • Non-condensables reduce recovery efficiency.
  • Contaminates recovered refrigerant.
  • Evacuation removes air and moisture from lines.

Memory trick: Hoses clear, no air to fear!

More Type I (Small Appliances) questions