A commercial building inspector is reviewing plans for a new three-story office building of Type IIA construction. The plans show a floor assembly with a 1-hour fire-resistance rating. What is the minimum fire-resistance rating required for the floor construction (including beams, girders, and trusses) in this building type, according to the IBC?

  1. A1.5 hours
  2. B2 hours
  3. C0 hours
  4. D1 hour
Show answer & explanation

Correct answer: D. 1 hour

According to IBC Table 601, for Type IIA construction, floor construction (including beams, girders, and trusses) is required to have a minimum 1-hour fire-resistance rating.

Why the other options are wrong

  • A. 1.5 hours is not a standard fire-resistance rating specified in IBC Table 601 for floor construction.
  • B. 2 hours is typically required for Type IB construction floors or higher-rated elements in Type IIA.
  • C. 0 hours is for Type IIB construction, which has no fire-resistance rating requirement for structural elements.

Type IIA Fire Rating

Type IIA construction is a noncombustible construction type where structural elements, including floors, are required to have a 1-hour fire-resistance rating.

  • Noncombustible construction.
  • Floor assemblies require 1-hour rating.
  • Bearing walls and structural frames also require 1-hour rating.
  • Less fire-resistive than Type IB.

Memory trick: Building types determine fire's might, check the table for your code's light.