Commercial Building Inspector B2Floor ConstructionMedium

A commercial building inspector is reviewing the plans for a new four-story mixed-use building. The structural drawings indicate that the floor system consists of steel beams and girders supporting a composite metal deck with a concrete slab. What is the minimum fire-resistance rating required for the floor construction separating a Group M occupancy from a Group R-2 occupancy in this building, constructed as Type IIIA?

  1. A3 hours
  2. B1 hour
  3. C2 hours
  4. D4 hours
Show answer & explanation

Correct answer: C. 2 hours

According to IBC Table 508.4, separations between different occupancies must have fire-resistance ratings as specified. For a Group M separated from a Group R-2, the required fire-resistance rating for the floor construction is 2 hours.

Why the other options are wrong

  • A. This rating is for higher hazard separations or specific structural elements in certain building types, not applicable here.
  • B. This is the required rating for some other occupancy separations or for non-bearing walls in certain building types, but not for M from R-2.
  • D. This rating is typically for very high hazard conditions or specific structural elements in high-rise buildings.

Occupancy Separation Fire Rating

The minimum fire-resistance rating required for an assembly that separates adjacent occupancies of different hazard levels within a building.

  • Determined by occupancy groups involved.
  • Found in IBC Table 508.4.
  • Critical for life safety and fire containment.

Memory trick: Occupancy separation ratings are like firewalls between different building functions.