Journeyman Plumber ExamGas PipingEasy

A plumber is installing a gas clothes dryer in a residential laundry room. The dryer requires a flexible connector for connection to the rigid gas piping. Which of the following is an essential requirement for the installation of this flexible connector?

  1. AIt must be listed for appliance connectors and not exceed 6 feet in length.
  2. BIt must be permanently attached to the appliance and not easily removable.
  3. CIt can be routed through an attic or crawl space if properly supported.
  4. DIt must be installed in a concealed location to protect it from damage.
Show answer & explanation

Correct answer: A. It must be listed for appliance connectors and not exceed 6 feet in length.

Flexible gas appliance connectors must be specifically listed for that purpose and typically have a maximum allowable length, often 6 feet, to minimize potential for damage or stress. They are not intended for concealed installation or long runs through spaces like attics.

Why the other options are wrong

  • B. Flexible connectors are designed to allow for easy disconnection of the appliance for service or replacement, so they are not permanently attached.
  • C. Flexible connectors are not designed or permitted for routing through concealed spaces like attics or crawl spaces; rigid piping should be used for such runs.
  • D. Flexible connectors are generally not permitted in concealed locations because they are more prone to damage and difficult to inspect.

Flexible Gas Appliance Connector

A corrugated metal or stainless steel tubing with fittings, used to connect a gas appliance to the rigid gas piping.

  • Must be listed for appliance connection.
  • Maximum length typically 6 feet.
  • Not for concealed installation.

Memory trick: Flex it right, keep it short, keep it exposed, for a safe gas report!